PDH

75/120(BNC/RF45) Patch Panel

Overview

16xE1 Impedance Converter Provide 16 channel G.703 75(BNC) to 120Ω(RJ45) Converter ,not need power;

Features

  • E1 75/120 Interface level conforms to the ITU-T G.703 level standard template;
  • 75 and 120 ohm impedance two-way signal conversion, easy to use
  • Without external power supply

Parameters

  • E1 Interface

E1 interface protocol: ITU-T G.703,
Interface Code:         HDB3;

Impedance:                      75Ω (unbalance BNC), 120Ω (balance RJ45);

Bit Rate 2048±50ppm
Impedance 75W Non Balance 120W Balance
The “mark” (pulse) nominal peak voltage 2.37V 3.0V
“Empty” (no pulse) nominal peak voltage 0±0.237V 0±0.3V
Nominal pulse width 244ns
Pulse width at the midpoint of the positive and negative pulse amplitude ratio 0.95~1.05
Nominal pulse amplitude, pulse width ratio of positive and negative half 0.95~1.05

 

  • Working Environment

Working temperature:    -40°C ~ 80°C
Working Humidity:            5%~95 % (no condensation)

Storage temperature:      -40°C ~ 85°C
Storage Humidity:                    5%~95 % (no condensation)

MTBF:                         >500,000 hours

Specifications

Model HY-C16E1
Functional Description 16xE1 Impedance Converter Provide 16 channel G.703 75(BNC) to 120Ω(RJ45) Converter
Port Description 16*75ohm  E1(BNC)+16*120 ohm E1(RJ45)
Power Not Need
Dimension 485(length) X 65(width) X45(height) mm(1U Rack Type)
Weight 1.0Kg/Pcs(DeskTop Type) ;